Page tree
Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Next »

Description

The FX Meter template allows you to display input, output and reduction meter for a number of effects like Compressor, Expander, LImiter, etc. It also contains text controls for peak values and switches for peak resets. The template contains a combination of controls that are already pre-assigned inside the template using "@parameter". You can exchange controls, remove them, or modify the used resources to customize the appearance of the template, provided that you keep the correct parameter connections as defined in the template. Since the template provides is set up to work with a whole range of effects, it contains elements that are not usable with certain effects, for example there is no need fo a reduction meter  for an EQ. In these cases you can remove the elements that are not needed from the template and save it as a variation.

The template is part of the Basic Controls library and requires HALion 6.2.20 or HALion Sonic(SE) 3.2.20 or higher.

On this page:

Template Properties

PropertyDescription 
Scope

Allows you to define to which eq the meter is connected

Example: Use Scope=@bus:0/@0:Studio EQ' to connect it to the first Studio EQ in the first bus.

 

Components and how they are used

Controls and Sub Templates

ItemDescription
In_Meter_Left

A meter control that is connected via Value=@VUInL with the left input channel of the effect

In_Meter_Right

A meter control that is connected via Value=@VUInL with the right input channel of the effect

Reduction_Meter

A meter control that is connected via Value=@GainReduction with the gain reduction output of the effect

Out_Meter_Left

A meter control that is connected via Value=@VUOutL with the left output channel of the effect

Out_Meter_Right

A meter control that is connected via Value=@VUOutR with the right output channel of the effect

Peak_In

A group containing two items

  • Peak_In_Reset: A switch that resets the input meter peak value. Its Value must be set to "@ResetInputVU"
  • Peak_In_Text: A text control that displays the input meter peak value. Its Value must be set to "@VUInMax"
Peak_Output

A group containing two items

  • Peak_Out_Reset: A switch that resets the output meter peak value. Its Value must be set to "@ResetOutputVU"
  • Peak_Out_Text: A text control that displays the output meter peak value. Its Value must be set to "@VUOutMax"
Peak_Reduction

A group containing two items

  • Peak_Reduction_Reset: A switch that resets the reduction meter peak value. Its Value must be set to "@ResetReduction"
  • Peak_Reduction_Text: A text control that displays the reduction meter peak value. Its Value must be set to "@maxgainreduction"
BackA background image.

All '@Parameter' connections used in the template only works inside this template

  • No labels