The FX Studio EQ Meter template allows you to display input, output and reduction meter for a number of effects like Compressor, Expander, LImiter, etcthe output of the Studio EQ module. It also contains a text controls control for peak values value and switches a switch for peak resets. The template contains a reset. This combination of controls that is are already pre-assigned inside the template using "@parameter". You can exchange controls, remove them, or modify the used resources to customize the appearance of the template, provided that you keep the correct parameter connections as defined in the template. Since the template provides is set up to work with a whole range of effects, it contains elements that are not usable with certain effects, for example there is no need fo a reduction meter  for an EQ. In these cases you can remove the elements that are not needed from the template and save it as a variation.

Note

The template is part of the Basic Controls library and requires HALion 6.2.20 or HALion Sonic(SE) 3.2.20 or higher.

Panel

On this page:

Table of Contents

Template Properties

PropertyDescription 
Scope

Allows you to define to which eq the meter is connected

Example: Use Scope=@bus:0/@0:Studio EQ' to connect it to the first Studio EQ in the first bus.

 

Components and how they are used

Controls and Sub Templates

ItemDescription
In_Meter_Left

A meter control that is connected via Value=@VUInL with the left input channel of the effect

In_Meter_Right

A meter control that is connected via Value=@VUInL with the right input channel of the effect

Reduction_Meter

A meter control that is connected via Value=@GainReduction with the gain reduction output of the effect

Out_Meter_Left

A meter control that is connected via Value=@VUOutL with the left output channel of the effectEQ

Out_Meter_Right

A meter control that is connected via Value=@VUOutR with the right output channel of the effectEQ

Peak_In

A group containing two items

  • Peak_In_Reset: A switch that resets the input meter peak value. Its Value must be set to "@ResetInputVU"
  • Peak_In_Text: A text control that displays the input meter peak value. Its Value must be set to "@VUInMax"
Peak_Output

A group containing two three items

  • Peak_Out_Reset: A switch that resets the output meter peak value. Its Value must be set to "@ResetOutputVU"
  • Peak_Out_Text: A text control that displays the output meter peak value. Its Value must be set to "@VUOutMax"
  • Peak_
Reduction

A group containing two items

  • Peak_Reduction_Reset: A switch that resets the reduction meter peak value. Its Value must be set to "@ResetReduction"
  • Peak_Reduction_Text: A text control that displays the reduction meter peak value. Its Value must be set to "@maxgainreduction"
  • Back: A background image
BackA background image for the meters.
Note

All '@Parameter' connections used in the template only works inside this template